User Tools

Site Tools


tailorcrete:examples:el_caleyo

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
tailorcrete:examples:el_caleyo [2012/07/25 16:21]
kolarfil
tailorcrete:examples:el_caleyo [2012/09/13 10:22]
bp Language check, formatting
Line 1: Line 1:
-==== El-Caleyo simulation ====+===== El-Caleyo simulation ​=====
  
-=== Test Setup and Geometry === +==== Test Setup and Geometry ​==== 
-So called ​El-Caleyo ​wall is special formwork with holes and angles designed ​to test filling ability of self-compacting concrete ​(SCC)Geometry ​of the formwork is on the picture below+This example illustrates the casting simulation of real problem. The test has been designed by El-Caleyo. The purpose of this tests is to assess the filling ability of self compacting concrete ​in complex formworks with complex geometry, containing several holes and rather dense traditional reinforcementThe geometry ​of the formwork is illustrated in Fig.1
  
-{{:​tailorcrete:​examples:​elcaleyo_geometry.jpg?​200|}}+|{{:​tailorcrete:​examples:​elcaleyo_geometry.jpg?​200|}}
 +|Fig.1: The geometry and setup of El-Caleyo wall|
  
-=== Computational Model === +==== Computational Model ==== 
-Simulations were done in two different ​ways of casting. In the first case, SCC is casted ​from the bottom of the specimen with constant input velocity. In the second case, SCC is casted from the top as it is usual in real casting.+Simulations were done for two different casting ​setups. In the first case, the SCC is pumped ​from the bottom of the specimen with prescribed ​constant input velocity. In the second case, SCC is casted from the top.
  
- == Casting from the bottom == +=== Casting from the bottom ===
- +
-Example of input file for the "​bottom casting"​ is here: {{:​tailorcrete:​examples:​elcaleyo.oofem.in|}} +
- +
-On the next picture, scheme of "​bottom casting"​ is shown. There is is prescribed velocity at the bottom edge. +
- +
-{{:​tailorcrete:​examples:​el_caleyo_t0.0.png?​200|}}+
  
 +Example of OOFEM input file for the "​bottom casting"​ sumulation can be dowloaded from here: {{:​tailorcrete:​examples:​elcaleyo.oofem.in|}}
  
 == Results == == Results ==
-Situation for evolving time is captured on pictures below+Initial setup of the model
- +|{{:​tailorcrete:​examples:​el_caleyo_t0.0.png?​200|}}|
-{{:​tailorcrete:​examples:​el_caleyo_t25.0.png?​200|}} +
- +
-{{:​tailorcrete:​examples:​el_caleyo_t100.0.png?​200|}}+
  
-{{:​tailorcrete:​examples:​el_caleyo_t175.0.png?​200|}} 
  
-{{:​tailorcrete:​examples:​el_caleyo_t400.0.png?​200|}} 
  
-== Casting from the top ==+The snapshots of solution, illustrating ​the position of SCC in different times, are presented below. 
 +|{{:​tailorcrete:​examples:​el_caleyo_t25.0.png?​200|}}|{{:​tailorcrete:​examples:​el_caleyo_t100.0.png?​200|}}| 
 +|{{:​tailorcrete:​examples:​el_caleyo_t175.0.png?​200|}}|{{:​tailorcrete:​examples:​el_caleyo_t400.0.png?​200|}}|
  
 +=== Casting from the top ===
  
-Example of input file for the "​casting from the top" ​is here:​{{:​tailorcrete:​examples:​elcaleyo_top_oofem.in|}}+Example of OOFEM input file for the simulation ​"​casting from the top" ​can be dowloaded from here:​{{:​tailorcrete:​examples:​elcaleyo_top_oofem.in|}}
  
-On the next picture, casting scheme is shown. SCC is initially at the reservoir above the wall.+On the next picture, casting scheme is shown. SCC is initially at the reservoir above the wall:
  
-{{:​tailorcrete:​examples:​el_caleyo_casting_from_the_top_t0.0.png?​200|}}+|{{:​tailorcrete:​examples:​el_caleyo_casting_from_the_top_t0.0.png?​200|}}|
  
  
tailorcrete/examples/el_caleyo.txt · Last modified: 2012/09/13 10:22 by bp